RadiForce RX560
21.3" Color LCD Monitor
This 5 megapixel, high-brightness color monitor has the high-definition display necessary for breast imaging. It combines ease-of-use, such as a narrow bezel design to help your eyes swiftly move from one monitor to another, with new functions to help you focus on your work and maintain high performance.
  • Contact EIZO
2 items
 
  • Features
  • Specifications
  • Documents Compatibility
  • Graphics Boards
  • QC Software & Tools Accessories

Case Studies

prev next

Making Each Life Visual


 

Evolve Your Image Reading

The RX560 MammoDuo integrates two RX560 monitors side by side on a specifically designed stand.

RadiForce RX560 MammoDuo
 

Distraction-Free Viewing

The monitor bezel is just 7.5 mm – the world's narrowest bezel on a 5 megapixel monitor; making the total distance between the visible screens of the two monitors only 15 mm. Furthermore, the bezel sits only 2.5 mm above the screen, making an almost completely flush bezel to easily switch your view between screens.
Distraction-Free Viewing

 

Space Saving

The dimensions of the RX560 MammoDuo are reduced by 67 mm horizontally, 36 mm vertically, and 20.5 mm in depth compared to a conventional side-by-side configuration with a single monitor of the same total resolution. The total space occupied by the monitors was reduced by 22%, creating a more unrestricted environment with expanded viewing space.

Space Saving1

Space Saving

 

Easy Adjustment

With the newly designed stand, you can adjust the height, tilt, and swivel of the two monitors without any gaps appearing between them.
 

Easy Adjustment_topdown Easy Adjustment_swivel


 

Clean and Sophisticated

The black front bezels are ideal for viewing the screen in dark reading rooms, making it easier to focus on images, while the original white stripe around the sides of the monitor presents a fresh, clean aesthetic.
Clean and Sophisticated

rx560_title_Reading_Space_04.jpg
 

The RadiForce RX560, sold as a single monitor with stand, is also available.



 

Evolve Your Image Reading

Work-and-Flow_logo.jpg

As more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO's unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow features with the RadiForce monitor and bundled RadiCS LE software.


Quick and Easy Focus

With the Point-and-Focus function, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of certain points on the screen to make interpretation easier.

Quick and Easy Focus

 

See more with animation gif_animation_icon

 


 

Full Color Support for Ultrasound, Breast CT and MRI

Breast cancer screenings are increasingly combining the use of mammography and ultrasound to view patients with high breast density. Furthermore, if breast cancer is suspected, various other tests may also be needed such as biopsy, breast MRI and CT.

The RX560 is the world's first medical monitor to use low temperature polysilicon (LTPS) liquid crystal display. Because of this, the color monitor can reach a brightness of up to 1100 cd/m2, similar to that of monochrome monitors. Due to this high brightness, the RX560 can display high-definition monochrome breast tomosynthesis and mammography images with deep blacks and no washout in addition to color images such as ultrasound and pathology.

Furthermore it has a high contrast ratio of 1500:1, approximating that of a monochrome monitor, displaying deep blacks without any washout.
Full Color Support for Ultrasound, Breast CT and MRI


 

Optimum Breast Screening Monitor

The monitor has obtained FDA 510(k) clearance by the U.S. Food and Drug Administration for breast tomosynthesis and mammography. This ensures that the monitor is capable of displaying detailed breast screening images where high performance is essential.

 

PinkRibbon


 

Display Both Monochrome and Color

Hybrid Gamma PXLThe Hybrid Gamma PXL function automatically distinguishes between monochrome and color images pixel by pixel, creating a hybrid display where each pixel has optimum grayscale; giving it greater accuracy and reliability than the conventional area-detection method.

In addition to breast tomosynthesis and mammography monochrome images, which require high display performance, the RX560 also faithfully reproduces color images such as breast MRI and CT, ultrasound, and pathology. This ultimately improves efficiency by allowing both monochrome and color images to be viewed on one screen.

Display Both Monochrome and Color
 

Visual Assessment

The Kumamoto Chuo Hospital, Japan, have conducted a visual assessment of the Hybrid Gamma PXL function included on the RadiForce monitor. Approximately a 37% improvement was noted when comparing the use of a color monitor with Hybrid Gamma PXL to one without it. In addition, Hybrid Gamma PXL was found to operate equally as well as monochrome monitors with GSDF when displaying monochrome images.
 

See the White Paper "The Advantages of Hybrid Gamma PXL" [PDF]

Visual Assessment

 

Smooth Display of Breast Tomosynthesis

The monitor has a response time of 12 milliseconds, making it ideal for enlarging and panning medical images, as well as quickly displaying breast tomosynthesis which comprises of several images in each shot.


Hassle-Free Multi-Monitor Configuration

The monitor is equipped with DisplayPort 1.2 input and output terminals. Using the output terminal allows you to easily configure several monitors in a daisy chain sequence without the hassle of excessive cabling.

A graphics board that supports daisy chain is necessary.
Daisychain


 

Variations for Specific User Needs

EIZO offers anti-glare (AG) and anti-reflection (AR) screen variations to suit user environments. AG treatment is ideal for exceptionally bright environments and drastically reduces glare from ambient lighting. AR treatment is ideal for moderately-lit environments to reduce mild screen glare while maintaining crisp text and images.

Read more about AR treatment [PDF]

Variations for Specific User Needs


 

Achieve Clarity True to the Source Data

A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD panel, the pixel aperture ratio has to be increased. This causes a typically unavoidable decline in sharpness. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored . This allows you to display an image safely on the monitor that is true to the original source data, even at high brightness levels.

MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 1.515 cycles/mm) the MTF increases by approximately 45%.
Sharpness Recovery

 

Clear, High Density Images

The monitor hosts 0.165 mm pixels, realizing a smooth, high-density, high-definition image without graininess.

 

Make the Precise Diagnosis

EIZO carefully measures and sets each grayscale tone to create a monitor compliant with DICOM Part 14. This ensures the most consistent shading possible, allowing for the most accurate diagnosis.

 

Make the Precise Diagnosis


 

Simple Calibration with Built-In Sensor

The monitor hosts an Integrated Front Sensor (IFS). It is built into the bezel and is only visible when in use; not needing any time to set up. By using it together with the included monitor control software RadiCS LE, brightness and gradation can be corrected to match DICOM Part 14 standards.


DICOM Part 14

Integrated Front Sensor


 

Experience Smooth Color Reproduction

The monitor supports 10-bit input for each RGB color, displaying more than one billion colors simultaneously. This ensures accurate color reproduction for images such as MRI, ultrasound, and pathology.

 

Comfortable View from Any Angle

Wide viewing angles allow you to view the screen from the side with minimal color shift, also permitting more than one person to view the monitor comfortably at the same time.
Comfortable View from Any Angle

 

View Accurate Images in Moments

The EIZO-patented drift correction function quickly stabilizes the brightness level of the monitor upon startup or wakeup from sleep mode, giving you the most accurate images quickly ready for viewing. In addition, a sensor measures the backlight brightness and automatically compensates for brightness fluctuations caused by ambient temperature and aging for a consistently stable display.
View Accurate Images in Moments

 

Attain Steady Images Across the Screen

The Digital Uniformity Equalizer (DUE) function helps to even out fluctuations in brightness and chroma on different parts of the screen to provide smoother images.

DUE


 

Select the Ideal Mode for Modalities

The CAL Switch function allows you to choose various modes for different modalities, such as mammography and breast MRI, ultrasound, and pathology, without the need to calibrate each time.

Using the bundled RadiCS LE software, modes can be set to automatically switch to optimal image viewing conditions with the click of a mouse or using the monitor's display mode.

Select the Ideal Mode for Modalities


 

Conserve Energy While Away

A presence sensor prompts the monitor to switch to power save mode when the user is away and resumes operation upon their return to conserve power when not in use. In the latest RadiForce models, the sensor detects the user's presence using a heat sensing method. This increases the range and angle of detection compared to conventional detection methods, making it effective when using multiple monitors.

Conserve Energy While Away


 

Improve Operability

EIZO's highly versatile stand offers tilt, swivel, and a wide height adjustment range, enabling you to use the monitor with greater comfort.

 

Stay Confident with Stable Brightness

EIZO's confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.

 

Mammography QC Standards Compliance

EIZO's easy-to-use RadiCS UX2 quality control software & calibration sensor (sold separately) performs precise calibration conforming to DICOM Part 14 and enables quality control (QC) complying with ACR Practice Guideline and other QC standard for digital mammography monitors.


 

Rest Assured with Medical Qualifications

The monitors meet the strictest medical, safety, and EMC emission standards.

Rest Assured with Medical Qualifications

Warranty with Safety and Trust

EIZO and its authorized distributors offer a five-year limited warranty.

 

 

Our Contribution to SDGs

As part of its sustainability initiatives, EIZO is contributing towards the United Nations' Sustainable Development Goals (SDGs).   SDGs Logo

Supporting a Healthy Life
Starting with our message “Making Each Life Visual”, we aim to support optimal medical care for each and every individual through accurate diagnosis and treatment afforded by our innovative healthcare technologies.
 
SDGs 03SDGs 08
     
Environmentally Conscious
Our healthcare products are designed to promote energy efficiency for reduced power consumption and greenhouse gas emissions, while maintaining the high performance and functionality needed in healthcare. We also implement a responsible after-service recycling system.
 
SDGs 07SDGs 12
Model Variations RX560-BK-MD: Anti-Glare coating, two screens, with dual stand, black
RX560-ARBK-MD: Anti-Reflection coating, two screens, with dual stand, black
RX560-BK: Anti-Glare coating, one screen, with stand, black
RX560-ARBK: Anti-Reflection coating, one screen, with stand, black
Panel  
Type Color (IPS)
Backlight LED
Size 21.3" (54.1 cm)
Native Resolution 2048 x 2560 (4:5 aspect ratio)
Viewable Image Size (H x V) 337.9 x 422.4 mm
Pixel Pitch (H x V) 0.165 x 0.165 mm
Display Colors 10-bit (DisplayPort): 1.07 billion from a palette of 543 billion (13-bit) colors
8-bit: 16.77 million from a palette of 543 billion (13-bit) colors
Viewing Angles (H / V, typical) 178° / 178°
Brightness (typical) 1100 cd/m2
Recommended Brightness for Calibration 500 cd/m2
Contrast Ratio (typical) 1500:1
Response Time (typical) 12 ms (black-white-black)
Video Signals  
Input Terminals DisplayPort, DVI-D (dual link)
Output Terminals DisplayPort (daisy chain)
Digital Scanning Frequency (H / V) 31 - 135 kHz / 23 - 61 Hz
USB  
Upstream USB 2.0: Type-B
Downstream USB 2.0: Type-A x 2
Power  
Power Input AC 100 - 240 V: 50 / 60 Hz
Typical Power Consumption 43 W
Maximum Power Consumption 87 W
Power Save Mode 1 W or less
Sensor Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor
Features & Functions  
Brightness Stabilization Yes
Digital Uniformity Equalizer Yes
Hybrid Gamma PXL Yes
Work-and-Flow Point-and-Focus
Preset Modes CAL Switch (DICOM, CAL1, CAL2, Custom, sRGB, Text)
OSD Languages English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
Physical Specifications  
Net Weight RX560-MD, RX560-AR-MD:
17.3 kg

RX560, RX560-AR:
8.1 kg
Net Weight (Without Stand) 5.3 kg
Hole Spacing (VESA Standard) 100 x 100 mm
Certifications & Standards (Please contact EIZO for the latest information.) RX560, RX560-AR:
CE / UKCA (Medical Device), ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No. 60601-1, IEC/EN60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC
FDA 510(k) Clearance for Breast Tomosynthesis, Mammography, and General Radiography
Dedicated Software  
Monitor Quality Control Software RadiCS Supported
Supplied Accessories (May vary by country. Please contact EIZO for details.)  
Signal Cables RX560-MD, RX560-AR-MD:
Dual Link DVI-D (3 m) x 2, DisplayPort (3 m) x 2, DisplayPort (1 m)

RX560, RX560-AR:
Dual Link DVI-D (3 m), DisplayPort (3 m)
Others RX560-MD, RX560-AR-MD:
AC power cord (3 m) x 2, USB Type-A - USB Type-B cable (3 m) x 2, Utility Disk (RadiCS LE, PDF installation manual), instructions for use

RX560, RX560-AR:
AC power cord (3 m), USB Type-A - USB Type-B cable (3 m), Utility Disk (RadiCS LE, PDF installation manual), instructions for use
Warranty 5 Years
Dimension Drawing PDF

Brochures

RadiForce general
14.4 MB

Download

 

Manuals

Languages

RX560 Instructions for Use English 1.47 MB PDF
RX560 Instructions for Use German 1.41 MB PDF
RX560 Instructions for Use French 1.41 MB PDF
RX560 Instructions for Use Russian 1.36 MB PDF
RX560 Instructions for Use Chinese-Simplified 2.02 MB PDF
RX560 Instructions for Use Chinese-Traditional 2.05 MB PDF
RX560 Installation Manual English 922 KB PDF
Additional Information for MammoDuo Model English
German
French
Russian
Chinese-Simplified
Chinese-Traditional
Japanese
8.02 MB PDF
RX560 Installation Manual German 956 KB PDF
RX560 Installation Manual French 978 KB PDF
RX560 Installation Manual Russian 961 KB PDF
RX560 Instructions for Use Italian 1.4 MB PDF
Additional Information for MammoDuo Model Italian 1.84 MB PDF
RX560 Instructions for Use Czech 1.33 MB PDF
Additional Information for MammoDuo Model Czech 1.83 MB PDF
RX560 Instructions for Use Swedish 1.36 MB PDF
Additional Information for MammoDuo Model Swedish 1.85 MB PDF
RX560 Installation Manual Chinese-Simplified 1.15 MB PDF
RX560 Installation Manual Chinese-Traditional 1.17 MB PDF
RX560 Instructions for Use Arabic 1.31 MB PDF
Additional Information for MammoDuo Model Arabic 1.83 MB PDF
RX560 Instructions for Use Danish 1.36 MB PDF
Additional Information for MammoDuo Model Danish 1.85 MB PDF
RX560 Instructions for Use Dutch 1.36 MB PDF
Additional Information for MammoDuo Model Dutch 1.85 MB PDF
RX560 Instructions for Use Finnish 1.33 MB PDF
Additional Information for MammoDuo Model Finnish 1.83 MB PDF
RX560 Instructions for Use Greek 1.36 MB PDF
Additional Information for MammoDuo Model Greek 1.82 MB PDF
RX560 Instructions for Use Korean 1.59 MB PDF
Additional Information for MammoDuo Model Korean 1.91 MB PDF
RX560 Instructions for Use Norwegian 1.35 MB PDF
Additional Information for MammoDuo Model Norwegian 1.85 MB PDF
RX560 Instructions for Use Polish 1.34 MB PDF
Additional Information for MammoDuo Model Polish 1.83 MB PDF
RX560 Instructions for Use Portuguese 1.36 MB PDF
Additional Information for MammoDuo Model Portuguese 1.85 MB PDF
RX560 Instructions for Use Spanish 1.36 MB PDF
Additional Information for MammoDuo Model Spanish 1.85 MB PDF
RX560 Instructions for Use Turkish 1.32 MB PDF
Additional Information for MammoDuo Model Turkish 1.83 MB PDF
RX560 Instructions for Use Estonian 1.34 MB PDF
Additional Information for MammoDuo Model Estonian 1.83 MB PDF
RX560 Instructions for Use Latvian 1.33 MB PDF
Additional Information for MammoDuo Model Latvian 1.84 MB PDF
RX560 Instructions for Use Lithuanian 1.35 MB PDF
Additional Information for MammoDuo Model Lithuanian 1.82 MB PDF
RX560 Instructions for Use Romanian 1.33 MB PDF
Additional Information for MammoDuo Model Romanian 1.83 MB PDF
RX560 Instructions for Use Slovak 1.33 MB PDF
Additional Information for MammoDuo Model Slovak 1.84 MB PDF
RX560 Instructions for Use Slovene 1.3 MB PDF
Additional Information for MammoDuo Model Slovene 1.83 MB PDF
RX560 Instructions for Use Hungarian 1.36 MB PDF
Additional Information for MammoDuo Model Hungarian 1.87 MB PDF
RX560 Instructions for Use Bulgarian 1.35 MB PDF
Additional Information for MammoDuo Model Bulgarian 1.84 MB PDF
RX560 Instructions for Use Croatian 1.33 MB PDF
Additional Information for MammoDuo Model Croatian 1.85 MB PDF

Compatibility

Date Subject
October 30, 2023 HP Z6 G5 Workstation and FlexScan, RadiForce Compatibility
August 3, 2023 HP Z4 G5 Workstation and FlexScan, RadiForce Compatibility
June 27, 2023 Compatibility between RadiForce monitors using DisplayPort daisy chains
November 1, 2022 HP Z2 SFF G9, Z2 Tower G9, Z2 Mini G9 Workstation and FlexScan, RadiForce Compatibility
February 1, 2022 HP Z2 SFF G5, Z2 Tower G5, Z2 G8 Tower Workstation and FlexScan, RadiForce Compatibility
June 24, 2021 Dell Precision 5820 Tower and RadiForce Compatibility
March 11, 2021 HP Z2 Mini G5, Z2 G5 SFF, Z2 Tower G5 Workstation and FlexScan, RadiForce Compatibility
April 14, 2020 Lenovo ThinkStation P330 SFF, P330 Tiny, P520c, ThinkPad P53, P53 (Thunderbolt 3 Dock) and FlexScan, RadiForce Compatibility
July 30, 2019 Abnormal Display Issue on Microsoft Windows 10 May 2019 Update (1903)
January 23, 2019 A USB signal transmission error may occur between some PCs and EIZO monitors when using EIZO software.
November 29, 2018 HP Z2 Mini G4 Workstation and RadiForce Compatibility
November 15, 2018 HP Z2 Tower G4, Z2 SFF G4 Workstation and RadiForce Compatibility
September 20, 2018 DELL T5820, T7820 and RadiForce Compatibility
March 15, 2018 HP Z240SFF, Z240, Z4 G4, Z6 G4, Z8 G4 Workstation and RadiForce Compatibility

Technical Information

November 22, 2017 The Advantages of Hybrid Gamma PXL [PDF]

This document shows the results of a study conducted by the Federation of National Public Service Personnel Mutual Aid Association of Kumamoto Chuo Hospital comparing the interpretation accuracy of color and monochrome images when the Hybrid Gamma PXL function is turned on or off.

Graphics Boards
MED-XN83

- EIZO original driver and bios
- Daisy chain supported

Recommended
Graphics Boards
MED-XN63

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN43

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN51LP

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN31LP

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN72

- EIZO original driver and bios
- Daisy chain supported

Quality Control Software & Tools
RadiCS UX2

- Quality Control Software
- UX2 Calibration Sensor bundled

Quality Control Software & Tools
UX2 Sensor

- Quality Control External Calibration Sensor

Comfort Light for Reading Rooms
RadiLight

- Comfort Light for Reading Rooms

Arms
LA-011-W

35° up tilt and 180° swivel wide adjustment range

Mounting Bracket
VESAMP100

VESA mounting plate for attaching an IP decoding box to certain FlexScan monitors using VOP-01

Panel Protector
RP-918

- Protect against dust and scratches
- Fit between screen and bezel
- Integrated Front Sensor usable

Cable
PP100

Short 1m DisplayPort cable

Monitor Cleaning Kit
ScreenCleaner

- Keep your screen free from dust and fingerprints
- Includes pump spray and cloth

 

  • Making Each Life Visual
  • Creating a Comfortable Reading Environment for Doctors
  • Choosing the Ideal Monitor for Teleradiology
  • RX1270 Case Study for Multi-Modality
  • RX1270 Case Study for Mammography
  • EIZO-Sponsored Seminars Supporting Early Detection of Breast Cancer
  • QC Standards for Medical Monitors
prev next